- moja uctovnicka ma tuto tlacku a zacalo jej vypisovat tuto hlasku pred tlacenim : Mate plny absorbcny zasobnik a treba ho vymenit - obratte sa na sevis.
Ak som to dobre pochopil tak je to zasobnik na boku kde si zasobniky odpluvaju atrament a ten je plny.
- otazka znie pada toto este do zaruky alebo to nespada do zaruky?
- alebo ci sa to nejako neda nejako vycistit ( moc sa do toho pustat nechcem kedze je este v zaruke.)
Nemate niekto s tymto skusenost?
Tlaciaren Canon iP1000 Pixma-plny absorbcny zasobnik
Nie som isty, ale ten vzneseny nazov "absorbcny zasobnik" neni tusim nic ine, ako spongia. Cize ak by ma ten zakrok mal vyjst 2000,- tak by som to asi riskol, zobral ihlu a injekciu a skusil ten sajrajt z neho vycucat... Ked sa to poserie, kupis novu tlaciaren, ked nie, budes sa tesit z usetrenych chechtakov
edit: este som nasiel toto - postup, ako zresetovat tlaciaren a vycistit tu blbost (je o tom cele forum http://www.fixyourownprinter.com/forums/ )
STEP 1:
- Disconnect printer from AC power
STEP 2:
- Press and HOLD the POWER button, and
connect printer to AC power
This simple power off procedure worked on my IP1500!
Cleaning the absorber was also easy. Power up with the cover open until the head moves to the left side then disconnect the power cord so the head is now positioned away from the pads.
The two pads can be lifted up easily with a pair of sharp tweezers then rinsed in running water. They will become white again and can be blotted with paper napkins then air dried in a warm location (I used an industrial oven set to 40°C). The wells in the rubber holder can be cleaned with cotton swabs before returning the two pads (left side first, then press down the right side).
postup mozno nebude uplne sediet, skus pohladat na tom fore
edit: este som nasiel toto - postup, ako zresetovat tlaciaren a vycistit tu blbost (je o tom cele forum http://www.fixyourownprinter.com/forums/ )
STEP 1:
- Disconnect printer from AC power
STEP 2:
- Press and HOLD the POWER button, and
connect printer to AC power
This simple power off procedure worked on my IP1500!
Cleaning the absorber was also easy. Power up with the cover open until the head moves to the left side then disconnect the power cord so the head is now positioned away from the pads.
The two pads can be lifted up easily with a pair of sharp tweezers then rinsed in running water. They will become white again and can be blotted with paper napkins then air dried in a warm location (I used an industrial oven set to 40°C). The wells in the rubber holder can be cleaned with cotton swabs before returning the two pads (left side first, then press down the right side).
postup mozno nebude uplne sediet, skus pohladat na tom fore